Command Format: [VERCnUi]
Cn = card ID number (n = slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = Unit ID (i = # from 0 to 9) (refer to the
MT100-100 user’s guide for explanation)
Example:
If one MT103-102 card is in slot #2 of unit 3:
To send command
[VERC2U3], the Multi-Tasker™
Enclosure will return:
MT103-102 690-0125-009
690-0125-009 = software version
MT103-102 = card type
2. [C]
This command receives the status of the card.
Command Format:
[CnUi]
Cn = card id (n = from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = unit id (i = from 0 to 9) (refer to the
MT100-100 user’s guide for explanation)
Example:
If one MT103-102 card is in slot #2 of unit 3 with
output 1 and 2 ON, HV enabled and output
enabled:
To send command
[C2U3], the Multi-Tasker
Enclosure will return feedback as [
On12 C02].
If there is no card plugged in slot #2 of unit 3: To
send command
[C2U3], the Multi-Tasker™
Enclosure will not return any feedback.
3. [CnS]
This command will display and save the card
ON/OFF status for card in slot n. This ensures
the card returns to the current configuration after
system power has been turned off.
4. [SIGCn]
This command checks to see if there is a signal
present on the Input connector. The feedback
will be either 1 for YES or 0 for NO.
5. [ON]
This command enables one or more outputs of a
single card or group of cards.
[OnmCnUiS] for a single card
This command enables output “m” without
affecting any other outputs.
Default when plugged in = ALL OFF
m = Output number (m = 1 to 3)
Cn = Card ID number (n = 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = Unit ID number (i = 0 to 9)
S = saves command to memory
Example:
1)
[ON12C5U3]: Turns ON only output 1 and 2 of
the MT103-102 card located in slot #5 of the
MT100-100 Enclosure with unit ID3.
2)
[ON3C5U3]: Turns ON only output 3 of the
MT103-102 card located in slot #5 of the
MT100-100 Enclosure with unit ID3. After the
[ON12C5U3] and [ON3C5U3] commands have
been executed, output 1, 2 and 3 will be ON.
3)
[ONC5U3]: Turns ON all outputs of the card.
[ONmGkUiS]: for a group of cards
This command enables output "m" for each card
in group "k" of unit "i".
m = card output (m = # from 1-3)
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
S = saves command to memory
Example:
1. [ON1G5U1]: Turns ON output 1 for each card
in group 5 of unit 1.
2. [ONG5U1]: Turns ON all outputs for each
card in group 5 of unit 1.
[ON…..P]: sets path
This command will set the path for the output, but
it is not active until the switch command [SW] is
executed. Commands ending in "P" are not
Vista de pagina 7