MULTI-TASKER
8
executed immediately. The path for outputs on
multiple cards or the same card can be loaded.
Command Format: [ONmCnUiP]
m = output number (m =1 to 3)
Cn = card ID No. (n = a slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = unit number (i = # from 0-9)
P = path
Example:
If 2 cards are in slot 6 and 7 of unit 3:
To enable output 1 of card 6 and output 3 of card
7 simultaneously, use the following commands:
[ON1C6U3P]
[ON3C7U3P]
[SW]
If "F" is included use the [ONmCnUiPF] command
or the [ONmCnUiFP]
command.
[ON…..F]: feedback
After processing a command, an OK or ER will be
returned as feedback if "F" is included at the end
of a command string or if the unit ID is zero.
Example:
[ON1C2U3F]: if path is not set
[ON1C2U3PF]: if path is set
6. [OFF]
This command disables one or more outputs of a
single card or a group of cards.
[OFFmCnUiS]: for a single card
This command disables output “m” without
affecting any other outputs.
m = output number (m = 1 to 3)
Cn = card ID No. (n = slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui= Unit ID number (i = 0 to 9)
S = saves command to memory
[OFFCnUi]: Turns OFF all outputs of the card
Example:
If card 5 of unit 3 has output 1, 2 and 3 ON:
a)
[OFF1C5U3]: Turns OFF output 1 while output
2 and 3 remain ON.
b)
[OFF23C5]: Turns OFF output 2 and 3.
c)
[OFFC5U3]: Turns OFF all outputs, which is
equivalent to
[OFF123C5U3].
[OFFmGkUiS]: for a group of cards
This command disables output "m" for each card
in group "k" of unit "i".
m = card output (m = # from 1-3)
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
S = saves command to memory
Example:
1. [OFF1G5U1]: Turns OFF output 1 for each
card in group 5 of unit 1.
2. [OFFG5U1]: Turns OFF all outputs for each
card in group 5 of unit 1.
[OFF…..P]: sets path
This command will set the path for the output, but
it is not active until the switch command [SW] is
executed. Commands ending in "P" are not
executed immediately. The path for outputs on
multiple cards or the same card can be loaded.
Command Format: [OFFmCnUiP]
m = number (m =1 to 3)
Cn = card ID No. (n = a slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = unit number (i = # from 0-9)
P = path
Example:
If 2 cards are in slot 6 and 7 of unit 3:
To enable output 1 and 2 of card 6 and output 3
and 4 of card 7 simultaneously, use the following
commands:
Vista de pagina 8